CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2023

CVE-2023-0321
Campbellsci Cr6 Firmware vulnerability

Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.

High priority: this vulnerability is rated critical and can be attacked over the network without a login.

Affected products

Cr6 Firmware, Cr300 Firmware, Cr800 Firmware, Cr1000 Firmware, Cr3000 Firmware. The exact versions are in the references.

What to do now

  • Check your exposureFind out whether Campbellsci Cr6 Firmware runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.

References

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.