The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
Affected products
Proclima. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Schneider-electric Proclima runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
- download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01 · Vendor Advisory
- ics-cert.us-cert.gov/advisories/ICSA-15-335-02 · Third Party Advisory
- www.zerodayinitiative.com/advisories/ZDI-15-626
- www.zerodayinitiative.com/advisories/ZDI-15-627
- www.zerodayinitiative.com/advisories/ZDI-15-628
- www.zerodayinitiative.com/advisories/ZDI-15-629
- nvd.nist.gov/vuln/detail/CVE-2015-8561
- cve.org/CVERecord?id=CVE-2015-8561