Siemens Sinumerik 808d V4.7 Firmware vulnerability

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known

High priority: this vulnerability is rated critical and can be attacked over the network without a login.

Affected products

Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 Firmware, Sinumerik 840d Sl V4.7 Firmware, Sinumerik 840d Sl V4.8 Firmware, Sinumerik 828d V4.7 Firmware. The exact versions are in the references.

What to do now

  • Check your exposureFind out whether Siemens Sinumerik 808d V4.7 Firmware runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.