CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2019 · Siemens

CVE-2019-13924
Siemens Scalance Xc-200 Firmware vulnerability

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Affected products

Scalance Xc-200 Firmware, Scalance Xf-200 Firmware, Scalance Xp-200 Firmware, Scalance X-200irt Firmware, Scalance Xb-200 Firmware, Scalance Xr-300wg Firmware, Scalance X-300 Firmware, Scalance Xr-300 Firmware. The exact versions are in the references.

What to do now

  • Check your exposureFind out whether Siemens Scalance Xc-200 Firmware runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.

References

More vulnerabilities in Siemens products

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.