Vulnerabilities · 2019 · Zyxel
CVE-2019-15800
Zyxel Gs1900-8 Firmware vulnerability
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
Affected products
Gs1900-8 Firmware, Gs1900-8hp Firmware, Gs1900-10hp Firmware, Gs1900-16 Firmware, Gs1900-24e Firmware, Gs1900-24 Firmware, Gs1900-24hp Firmware, Gs1900-48 Firmware, Gs1900-48hp Firmware. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Zyxel Gs1900-8 Firmware runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
More vulnerabilities in Zyxel products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.