Siemens Sinvr 3 Central Control Server vulnerability
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains a directory traversal vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker with network access to the CCS server could exploit this vulnerability to list arbitrary directories or read files outside of the CCS application context.
Affected products
Sinvr 3 Central Control Server, Sinvr 3 Video Server. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Siemens Sinvr 3 Central Control Server runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Set the orderSystems that can be reached from the internet come first, then the rest.