Vulnerabilities · 2020 · Iobit
CVE-2020-10234
Iobit Advanced Systemcare vulnerability
The AscRegistryFilter.sys kernel driver in IObit Advanced SystemCare 13.2 allows an unprivileged user to send an IOCTL to the device driver. If the user provides a NULL entry for the dwIoControlCode parameter, a kernel panic (aka BSOD) follows. The IOCTL codes can be found in the dispatch function: 0x8001E000, 0x8001E004, 0x8001E008, 0x8001E00C, 0x8001E010, 0x8001E014, 0x8001E020, 0x8001E024, 0x8001E040, 0x8001E044, and 0x8001E048. \DosDevices\AscRegistryFilter and \Device\AscRegistryFilter are affected.
Affected products
Advanced Systemcare. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Iobit Advanced Systemcare runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Set the orderSystems that can be reached from the internet come first, then the rest.
References
More vulnerabilities in Iobit products
CVE-2024-12662CVE-2024-12661CVE-2024-12660CVE-2024-12659CVE-2024-12658CVE-2024-12657CVE-2024-7325CVE-2024-1195All 69
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.