CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2020 · Rockwellautomation

CVE-2020-5801
Rockwellautomation Factorytalk Linx vulnerability

An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.

Affected products

Factorytalk Linx. The exact versions are in the references.

What to do now

  • Check your exposureFind out whether Rockwellautomation Factorytalk Linx runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.

References

More vulnerabilities in Rockwellautomation products

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.