Vulnerabilities · 2020 · Rockwellautomation
CVE-2020-6967
Rockwellautomation Factorytalk Services Platform vulnerability
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
Affected products
Factorytalk Services Platform. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Rockwellautomation Factorytalk Services Platform runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
More vulnerabilities in Rockwellautomation products
CVE-2025-11918CVE-2025-9466CVE-2025-9465CVE-2025-9464CVE-2025-9364CVE-2025-9283CVE-2025-9282CVE-2025-9281All 337
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.