Vulnerabilities · 2021 · Siemens
CVE-2021-25663
Siemens Capital Vstar vulnerability
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
Affected products
Capital Vstar, Nucleus Net, Nucleus Readystart, Nucleus Source Code. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Siemens Capital Vstar runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
More vulnerabilities in Siemens products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.