CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2021 · Govicture

CVE-2021-43283
Govicture Wr1200 Firmware vulnerability

An issue was discovered on Victure WR1200 devices through 1.0.3. A command injection vulnerability was found within the web interface of the device, allowing an attacker with valid credentials to inject arbitrary shell commands to be executed by the device with root privileges. This occurs in the ping and traceroute features. An attacker would thus be able to use this vulnerability to open a reverse shell on the device with root privileges.

Affected products

Wr1200 Firmware. The exact versions are in the references.

What to do now

  • Check your exposureFind out whether Govicture Wr1200 Firmware runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Set the orderSystems that can be reached from the internet come first, then the rest.

References

More vulnerabilities in Govicture products

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.