Level1 Wbr-6012 Firmware vulnerability
A security flaw involving hard-coded credentials in LevelOne WBR-6012's web services allows attackers to gain unauthorized access during the first 30 seconds post-boot. Other vulnerabilities can force a reboot, circumventing the initial time restriction for exploitation.The password string can be found at addresses 0x 803cdd0f and 0x803da3e6: 803cdd0f 41 72 69 65 ds "AriesSerenaCairryNativitaMegan" 73 53 65 72 65 6e 61 43 ... It is referenced by the function at 0x800b78b0 and simplified in the pseudocode below: if (is_equal = strcmp(password,"AriesSerenaCairryNativitaMegan"){ ret = 3;} Where 3 is the return value to user-level access (0 being fail and 1 being admin/backdoor). While there's no legitimate functionality to change this password, once authenticated it is possible manually make a change by taking advantage of TALOS-2024-XXXXX using HTTP POST paramater "Pu" (new user password) in place of "Pa" (new admin password).