Vulnerabilities · 2025 · Juniper
CVE-2025-30645
Juniper Junos vulnerability
A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS). Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition. On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts. This issue affects Junos OS on SRX Series: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S5, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2.
Affected products
Junos. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Juniper Junos runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
More vulnerabilities in Juniper products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.