CVE-2025-71284
Synway SMG Gateway Management Software contains an OS command …
Synway SMG Gateway Management Software contains an OS command injection vulnerability in the RADIUS configuration endpoint at /en/9-2radius.php where the radius_address POST parameter is split and interpolated directly into a sed command without sanitization. An unauthenticated remote attacker can inject arbitrary shell commands by submitting a POST request with crafted radius_address, radius_address2, shared_secret2, source_ip, timeout, or retry parameters along with save=1 and enable_radius=1 to achieve remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-11 (UTC).
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
What to do now
- Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
- github.com/projectdiscovery/nuclei-templates/blob/main/http/vulnerabilities/synway/synways
- mp.weixin.qq.com/s/PyepoFSuQ63E3RnpQa9nsA
- mrxn.net/jswz/synway-9-2radius-rce.html
- www.synway.net/
- www.vulncheck.com/advisories/synway-smg-gateway-management-software-os-command-injection-v
- nvd.nist.gov/vuln/detail/CVE-2025-71284
- cve.org/CVERecord?id=CVE-2025-71284
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.