In the Aliro access control reference applications of the Nordic …
In the Aliro access control reference applications of the Nordic Semiconductor nRF Door Lock and Access Control Add-on v1.0.0 through v1.1.1, the stored Access Document record does not retain validFrom and validUntil. The cached public key path (VerifyPublicKey()) and the Kpersistent fast path (_VerifyKPersistentKey()) therefore never re-evaluate the Access Document validity period. An attacker who held a time-limited Aliro credential that was valid when first presented can continue to obtain physical access after the Access Document has expired, for as long as the cached record remains available. Fixed in v1.2.0.
What to do now
- Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Set the orderSystems that can be reached from the internet come first, then the rest.