CVE-2026-110240
Lancet through 2.3.9 contains an SSRF protection bypass …
Lancet through 2.3.9 contains an SSRF protection bypass vulnerability in netutil.IsInternalIP that misclassifies IPv6 private, link-local, CGNAT and transition addresses as external. Attackers can supply hostnames resolving to these address forms, including NAT64, 6to4 or Teredo embedding internal IPv4, to reach internal services or cloud metadata endpoints.
What to do now
- Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
- github.com/duke-git/lancet
- github.com/duke-git/lancet/blob/v1.4.6/netutil/net.go#L158-L170
- github.com/duke-git/lancet/blob/v2.3.9/netutil/net.go#L192-L205
- github.com/duke-git/lancet/commit/835111c832939a85416d686a1e99d5fe7060c9b4
- github.com/duke-git/lancet/issues/356
- github.com/duke-git/lancet/pull/357
- www.vulncheck.com/advisories/lancet-through-2.3.9-ssrf-protection-bypass-via-netutil-isint
- nvd.nist.gov/vuln/detail/CVE-2026-110240
- cve.org/CVERecord?id=CVE-2026-110240
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.