CVE-2026-21910
An Improper Check for Unusual or Exceptional Conditions …
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS on EX4k Series and QFX5k Series platforms allows an unauthenticated network-adjacent attacker flapping an interface to cause traffic between VXLAN Network Identifiers (VNIs) to drop, leading to a Denial of Service (DoS). On all EX4k and QFX5k platforms, a link flap in an EVPN-VXLAN configuration Link Aggregation Group (LAG) results in Inter-VNI traffic dropping when there are multiple load-balanced next-hop routes for the same destination. This issue is only applicable to systems that support EVPN-VXLAN Virtual Port-Link Aggregation Groups (VPLAG), such as the QFX5110, QFX5120, QFX5200, EX4100, EX4300, EX4400, and EX4650. Service can only be restored by restarting the affected FPC via the 'request chassis fpc restart slot <slot-number>' command. This issue affects Junos OS on EX4k and QFX5k Series: * all versions before 21.4R3-S12, * all versions of 22.2 * from 22.4 before 22.4R3-S8, * from 23.2 before 23.2R2-S5, * from 23.4 before 23.4R2-S5, * from 24.2 before 24.2R2-S3, * from 24.4 before 24.4R2.
What to do now
- Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Set the orderSystems that can be reached from the internet come first, then the rest.
References
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.