CVE-2026-35090
In Slican telephone exchanges it is possible to manage the control …
In Slican telephone exchanges it is possible to manage the control panel remotely. An unauthenticated attacker can connect to the modem via a telephone with a specific caller ID. This allows them to bypass admin authentication and gain full access to the service protocol and configuration panel. This vulnerability is independent of the telephone exchanges configuration. If remote access is disabled, calling with this caller ID will temporarily enable it. This issue was fixed in versions below: - IPL-256: version 6.61.0040 - IPM-032: version 6.61.0040 - CCT-1668: version 6.56.0430 - MAC-6400: version 6.56.0430 - CXS-0424: version 6.30.0510 The issue STILL EXISTS in End-Of-Life telephone exchanges in versions 4.xx and below: - CCT-1668 (CCT1CPU) - MAC-6400 - CXS-0424 These products were discontinued in 2011 and 2012 and and will not receive updates. These products require a hardware update in order to receive a software update. The vendor recommends that users of these devices contact the their service department directly to determine the options for upgrading.
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
What to do now
- Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.