CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2026

CVE-2026-62258
HTSlib is a library for reading and writing bioinformatics file …

HTSlib is a library for reading and writing bioinformatics file formats. Prior to 1.21.2, 1.22.3, 1.23.2, and 1.24, the CRAM decoder validates the 254-character query-name limit only after decoding the name into a 1024-byte stack array. An attacker-controlled CRAM record can provide an overlong query name and overflow the local stack buffer before the later validation runs; all CRAM format versions are affected. Opening such a file can crash the process, corrupt stack data, and may permit arbitrary code execution. This issue is fixed in versions 1.21.2, 1.22.3, 1.23.2, and 1.24.

What to do now

  • Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.

References

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.