CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2026

CVE-2026-81938
Grafana Mimir's Alertmanager rejects tenant-supplied receiver …

Grafana Mimir's Alertmanager rejects tenant-supplied receiver configurations that reference local files, but the check did not cover two HTTP client settings: http_headers.<name>.files and basic_auth.username_file. A tenant permitted to upload an Alertmanager configuration could point these fields at any file readable by the Alertmanager process. When a notification was sent, Alertmanager read the file and put its contents in a header of the outgoing request. By directing the receiver at a server they control, the tenant could read files from the Alertmanager host, such as credentials and configuration. Exploitation requires permission to write the tenant's Alertmanager configuration. Grafana Enterprise Metrics (GEM), which is built on Mimir, is also affected. The issue is fixed in Mimir 3.1.7 and 3.2.2 and in GEM 2.17.20. GEM 2.11 through 2.16 will not receive a fix; users on those versions should upgrade to 2.17.20 or later.

What to do now

  • Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Set the orderSystems that can be reached from the internet come first, then the rest.

References

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.