CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2026

CVE-2026-85068
Network UPS Tools is a collection of programs which provide a …

Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.4.2 through 2.8.5, ippon_command in drivers/blazer_usb.c partially initializes char tmp[64] with a short Megatec status query and then passes a fixed eight-byte chunk to usb_control_msg. A malicious firmware-controlled USB device presenting the Mustek Powermust VID 0x06da and Mustek Powermust PID 0x0003 matches blazer_usb_id, selects ippon_subdriver, and can receive the uninitialized trailing stack bytes during normal polling. The disclosure is bounded and read-only, requires physical or supply-chain access to the USB bus, and has no established integrity or availability impact. This issue is scheduled to be fixed in version 2.8.6.

What to do now

  • Check your exposureFind out whether the affected software runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Set the orderSystems that can be reached from the internet come first, then the rest.

References

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.