Endress
23 vulnerabilities.
All published vulnerabilities with a CVE number in Endress products, newest first, with severity and references.
| CVE | Summary | Published | CVSS |
|---|---|---|---|
| CVE-2025-27461 | Endress Meac300-fnade4 Firmware: During startup, the device automatically logs in the EPC2 Windows user without requesting a password. | 2025-07-03 | 7.6 |
| CVE-2025-27460 | Endress Meac300-fnade4 Firmware: The hard drives of the device are not encrypted using a full volume encryption feature such as BitLocker. This allows an attacker with physical … | 2025-07-03 | 7.6 |
| CVE-2025-27459 | Endress Meac300-fnade4 Firmware: The VNC application stores its passwords encrypted within the registry but uses DES for encryption. As DES is broken, the original passwords can be … | 2025-07-03 | 4.4 |
| CVE-2025-27458 | Endress Meac300-fnade4 Firmware: The VNC authentication mechanism bases on a challenge-response system where both server and client use the same password for encryption. The … | 2025-07-03 | 6.5 |
| CVE-2025-27457 | Endress Meac300-fnade4 Firmware: All communication between the VNC server and client(s) is unencrypted. This allows an attacker to intercept the traffic and obtain sensitive data. | 2025-07-03 | 6.5 |
| CVE-2025-27456 | Endress Meac300-fnade4 Firmware: The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time … | 2025-07-03 | 7.5 |
| CVE-2025-27455 | Endress Meac300-fnade4 Firmware: The web application is vulnerable to clickjacking attacks. The site can be embedded into another frame, allowing an attacker to trick a user into … | 2025-07-03 | 4.3 |
| CVE-2025-27454 | Endress Meac300-fnade4 Firmware: The application is vulnerable to cross-site request forgery. An attacker can trick a valid, logged in user into submitting a web request that they … | 2025-07-03 | 4.3 |
| CVE-2025-27453 | Endress Meac300-fnade4 Firmware: The HttpOnly flag is set to false on the PHPSESSION cookie. Therefore, the cookie can be accessed by other sources such as JavaScript. | 2025-07-03 | 5.3 |
| CVE-2025-27452 | Endress Meac300-fnade4 Firmware: The configuration of the Apache httpd webserver which serves the MEAC300-FNADE4 web application, is partly insecure. There are modules activated … | 2025-07-03 | 5.3 |
| CVE-2025-27451 | Endress Meac300-fnade4 Firmware: For failed login attempts, the application returns different error messages depending on whether the login failed due to an incorrect password or a … | 2025-07-03 | 5.3 |
| CVE-2025-27450 | Endress Meac300-fnade4 Firmware: The Secure attribute is missing on multiple cookies provided by the MEAC300-FNADE4. An attacker can trick a user to establish an unencrypted HTTP … | 2025-07-03 | 6.5 |
| CVE-2025-27449 | Endress Meac300-fnade4 Firmware: The MEAC300-FNADE4 does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it … | 2025-07-03 | 7.5 |
| CVE-2025-27448 | Endress Meac300-fnade4 Firmware: The web application is susceptible to cross-site-scripting attacks. An attacker who can create new dashboards can inject JavaScript code into the … | 2025-07-03 | 6.8 |
| CVE-2025-27447 | Endress Meac300-fnade4 Firmware: The web application is susceptible to cross-site-scripting attacks. An attacker can create a prepared URL, which injects JavaScript code into the … | 2025-07-03 | 7.4 |
| CVE-2025-1711 | Endress Meac300-fnade4 Firmware: Multiple services of the DUT as well as different scopes of the same service reuse the same credentials. | 2025-07-03 | 4.3 |
| CVE-2025-1710 | Endress Meac300-fnade4 Firmware: The maxView Storage Manager does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, … | 2025-07-03 | 7.5 |
| CVE-2025-1709 | Endress Meac300-fnade4 Firmware: Several credentials for the local PostgreSQL database are stored in plain text (partially base64 encoded). | 2025-07-03 | 6.5 |
| CVE-2025-1708 | Endress Meac300-fnade4 Firmware: The application is vulnerable to SQL injection attacks. An attacker is able to dump the PostgreSQL database and read its content. | 2025-07-03 | 8.6 |
| CVE-2024-6596 | Endress Echo Curve Viewer: An unauthenticated remote attacker can run malicious c# code included in curve files and execute commands in the users context. | 2024-09-10 | 9.8 |
| CVE-2020-12496 | Endress Rsg35 Firmware: Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) and Memograph M (Neutral/Private Label) (RSG45, ORSG45) with Firmware version … | 2020-11-19 | 6.5 |
| CVE-2020-12495 | Endress Rsg35 Firmware: Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) with Firmware version prior to V2.0.0 is prone to improper privilege management. … | 2020-11-19 | 9.1 |
| CVE-2018-16059 | Endress Wirelesshart Fieldgate Swg70 Firmware: Endress+Hauser WirelessHART Fieldgate SWG70 3.x devices allow Directory Traversal via the fcgi-bin/wgsetcgi filename parameter. | 2018-09-07 | 5.3 |
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.
Too many to
patch at once?
Providers for vulnerability management find the affected systems in your environment, set the order and keep the patching going.