CVE-2023-40710Opto22 Snap Pac S1 Firmware: An adversary could cause a continuous restart loop to the entire device by sending a large quantity of HTTP GET requests if the controller has the …2023-08-246.8
CVE-2023-40709Opto22 Snap Pac S1 Firmware: An adversary could crash the entire device by sending a large quantity of ICMP requests if the controller has the built-in web server enabled but …2023-08-246.8
CVE-2023-40708Opto22 Snap Pac S1 Firmware: The File Transfer Protocol (FTP) port is open by default in the SNAP PAC S1 Firmware version R10.3b. This could allow an adversary to access some …2023-08-245.8
CVE-2023-40707Opto22 Snap Pac S1 Firmware: There are no requirements for setting a complex password in the built-in web server of the SNAP PAC S1 Firmware version R10.3b, which could allow …2023-08-248.6
CVE-2023-40706Opto22 Snap Pac S1 Firmware: There is no limit on the number of login attempts in the web server for the SNAP PAC S1 Firmware version R10.3b. This could allow for a brute-force …2023-08-248.6
CVE-2020-12046Opto22 Softpac Project: Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker …2020-05-145.7
CVE-2020-12042Opto22 Softpac Project: Opto 22 SoftPAC Project Version 9.6 and prior. Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a …2020-05-146.5
CVE-2020-10620Opto22 Softpac Project: Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC communication does not include any credentials. This allows an attacker with network access …2020-05-149.8
CVE-2020-10616Opto22 Softpac Project: Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC does not specify the path of multiple imported .dll files. Therefore, an attacker can …2020-05-148.8
CVE-2020-10612Opto22 Softpac Project: Opto 22 SoftPAC Project Version 9.6 and prior. SoftPACAgent communicates with SoftPACMonitor over network Port 22000. However, this port is open …2020-05-149.1
CVE-2018-14807Opto22 Pac Control: A stack-based buffer overflow vulnerability in Opto 22 PAC Control Basic and PAC Control Professional versions R10.0a and prior may allow remote …2018-10-189.8
CVE-2015-1007Opto22 Optodatalink: A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote …2019-03-257.8
CVE-2015-1006Opto22 Optodatalink: A vulnerable file in Opto 22 PAC Project Professional versions prior to R9.4006, PAC Project Basic versions prior to R9.4006, PAC Display Basic …2019-05-109.8