CVE-2017-5569
Eclinicalworks Patient Portal vulnerability
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the template.jsp, which can be exploited without the need of authentication and via an HTTP POST request, and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
Affected products
Patient Portal. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Eclinicalworks Patient Portal runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
- www.securityfocus.com/bid/95741 · Third Party Advisory
- gist.github.com/malerisch/d32d127a002ac1f10bce39333ca9a4dc · Third Party Advisory
- nvd.nist.gov/vuln/detail/CVE-2017-5569
- cve.org/CVERecord?id=CVE-2017-5569
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.