Vulnerabilities · 2018 · Infoblox
CVE-2018-10239
Infoblox Nios vulnerability
A privilege escalation vulnerability in the "support access" feature on Infoblox NIOS 6.8 through 8.4.1 could allow a locally authenticated administrator to temporarily gain additional privileges on an affected device and perform actions within the super user scope. The vulnerability is due to a weakness in the "support access" password generation algorithm. A locally authenticated administrative user may be able to exploit this vulnerability if the "support access" feature is enabled, they know the support access code for the current session, and they know the algorithm to generate the support access password from the support access code. "Support access" is disabled by default. When enabled, the access will be automatically disabled (and support access code will expire) after the 24 hours.
Affected products
Nios. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Infoblox Nios runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Set the orderSystems that can be reached from the internet come first, then the rest.
References
More vulnerabilities in Infoblox products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.