Vulnerabilities · 2019 · Zyxel
CVE-2019-15803
Zyxel Gs1900-8 Firmware vulnerability
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Through an undocumented sequence of keypresses, undocumented functionality is triggered. A diagnostics shell is triggered via CTRL-ALT-t, which prompts for the password returned by fds_sys_passDebugPasswd_ret(). The firmware contains access control checks that determine if remote users are allowed to access this functionality. The function that performs this check (fds_sys_remoteDebugEnable_ret in libfds.so) always return TRUE with no actual checks performed. The diagnostics menu allows for reading/writing arbitrary registers and various other configuration parameters which are believed to be related to the network interface chips.
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
Affected products
Gs1900-8 Firmware, Gs1900-8hp Firmware, Gs1900-10hp Firmware, Gs1900-16 Firmware, Gs1900-24e Firmware, Gs1900-24 Firmware, Gs1900-24hp Firmware, Gs1900-48 Firmware, Gs1900-48hp Firmware. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Zyxel Gs1900-8 Firmware runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
More vulnerabilities in Zyxel products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.