Vulnerabilities · 2021 · Schneider-electric
CVE-2021-22779
Schneider-electric Ecostruxure Control Expert vulnerability
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
Affected products
Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect, Modicon M580 Bmep581020 Firmware, Modicon M580 Bmep581020h Firmware, Modicon M580 Bmep582020 Firmware, Modicon M580 Bmep582020h Firmware, Modicon M580 Bmep582040 Firmware, Modicon M580 Bmep582040h Firmware, Modicon M580 Bmep582040s Firmware and more. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Schneider-electric Ecostruxure Control Expert runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
More vulnerabilities in Schneider-electric products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.