Vulnerabilities · 2021 · Hitachienergy
CVE-2021-27196
Hitachienergy Relion 670 Firmware vulnerability
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.
Affected products
Relion 670 Firmware, Relion 650 Firmware, Relion Sam600-io Firmware, Rtu500 Firmware, Reb500 Firmware, Fox615 Tego1 Firmware, Modular Switchgear Monitoring Firmware, Gms600 Firmware, Pwc600 Firmware. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Hitachienergy Relion 670 Firmware runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
- search.abb.com/library/Download.aspx?DocumentID=9AKK107991A8932&LanguageCode=en&DocumentPa · Vendor Advisory
- search.abb.com/library/Download.aspx?DocumentID=9AKK107991A8934&LanguageCode=en&DocumentPa · Vendor Advisory
- search.abb.com/library/Download.aspx?DocumentID=9AKK107991A8936&LanguageCode=en&DocumentPa · Vendor Advisory
- search.abb.com/library/Download.aspx?DocumentID=9AKK107991A8937&LanguageCode=en&DocumentPa · Vendor Advisory
- search.abb.com/library/Download.aspx?DocumentID=9AKK107991A9057&LanguageCode=en&DocumentPa · Vendor Advisory
- search.abb.com/library/Download.aspx?DocumentID=9AKK107991A9058&LanguageCode=en&DocumentPa · Vendor Advisory
- search.abb.com/library/Download.aspx?DocumentID=9AKK107991A9059&LanguageCode=en&DocumentPa · Vendor Advisory
- nvd.nist.gov/vuln/detail/CVE-2021-27196
- cve.org/CVERecord?id=CVE-2021-27196
More vulnerabilities in Hitachienergy products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.