Vulnerabilities · 2018 · Moxa
CVE-2018-11421
Moxa Oncell G3150-hspa Firmware vulnerability
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
High priority: this vulnerability is rated critical and can be attacked over the network without a login.
Affected products
Oncell G3150-hspa Firmware, Oncell G3150-hspa-t Firmware. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Moxa Oncell G3150-hspa Firmware runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.
References
More vulnerabilities in Moxa products
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.