27 vulnerabilities.

All published vulnerabilities with a CVE number in Baxter products, newest first, with severity and references.

CVESummaryPublishedCVSS
CVE-2024-6796Baxter Connex Health Portal: In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an …2024-09-098.2
CVE-2024-6795Baxter Connex Health Portal: In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to …2024-09-0910.0
CVE-2022-26394Baxter Spectrum Wireless Battery Module Firmware: The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the …2022-09-095.5
CVE-2022-26393Baxter Spectrum Wireless Battery Module Firmware: The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to …2022-09-095.0
CVE-2022-26392Baxter Spectrum Wireless Battery Module Firmware: The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format …2022-09-093.1
CVE-2022-26390Baxter Spectrum Wireless Battery Module Firmware: The Baxter Spectrum Wireless Battery Module (WBM) stores network credentials and PHI (only applicable to Spectrum IQ pumps using auto programming) …2022-09-094.2
CVE-2021-43935Baxter Welch Allyn Connex Cardio: The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the …2021-12-158.1
CVE-2020-12048Baxter Phoenix X36 Firmware: Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) …2020-06-297.5
CVE-2020-12047Baxter Sigma Spectrum Infusion System Firmware: The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default …2020-06-299.8
CVE-2020-12045Baxter Sigma Spectrum Infusion System Firmware: The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates …2020-06-299.8
CVE-2020-12043Baxter Sigma Spectrum Infusion System Firmware: The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM …2020-06-299.8
CVE-2020-12041Baxter Sigma Spectrum Infusion System Firmware: The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM …2020-06-299.4
CVE-2020-12040Baxter Sigma Spectrum Infusion System Firmware: Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application …2020-06-299.8
CVE-2020-12039Baxter Sigma Spectrum Infusion System Firmware: Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 …2020-06-292.4
CVE-2020-12037Baxter Prismaflex Firmware: Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) …2020-06-297.5
CVE-2020-12036Baxter Prismaflex Firmware: Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) …2020-06-297.5
CVE-2020-12035Baxter Prismaflex Firmware: Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides …2020-06-294.9
CVE-2020-12032Baxter Em2400 Firmware: Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an …2020-06-299.1
CVE-2020-12024Baxter Em2400 Firmware: Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB …2020-06-296.1
CVE-2020-12020Baxter Em2400 Firmware: Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users …2020-06-296.1
CVE-2020-12016Baxter Em2400 Firmware: Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter …2020-06-299.8
CVE-2020-12012Baxter Em2400 Firmware: Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter …2020-06-296.1
CVE-2020-12008Baxter Em2400 Firmware: Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information …2020-06-297.5
CVE-2014-5434Baxter Sigma Spectrum Infusion System Firmware: Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with …2019-03-269.8
CVE-2014-5433Baxter Sigma Spectrum Infusion System Firmware: An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter …2019-03-269.8
CVE-2014-5432Baxter Sigma Spectrum Infusion System Firmware: Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port …2019-03-269.8
CVE-2014-5431Baxter Sigma Spectrum Infusion System Firmware: Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, …2019-03-266.8