CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2017 · Rockwellautomation

CVE-2017-14469
Rockwellautomation Micrologix 1400 B Firmware vulnerability

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0028 Fault Type: Non-User Description: Values 0x01 and 0x02 are invalid values for the user fault routine. By writing directly to the file it is possible to set these values. When this is done and the device is moved into a run state, a fault is triggered. NOTE: This is not possible through RSLogix.

High priority: this vulnerability is rated critical and can be attacked over the network without a login.

Affected products

Micrologix 1400 B Firmware. The exact versions are in the references.

What to do now

  • Check your exposureFind out whether Rockwellautomation Micrologix 1400 B Firmware runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Limit access until thenIf you cannot update at once, take the system off the internet or restrict who can reach it.

References

More vulnerabilities in Rockwellautomation products

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.