Vulnerabilities · 2012 · Siemens
CVE-2012-2441
Siemens Ruggedcom Rugged Operating System vulnerability
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.
Affected products
Ruggedcom Rugged Operating System. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Siemens Ruggedcom Rugged Operating System runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Set the orderSystems that can be reached from the internet come first, then the rest.
References
- www.ruggedcom.com/productbulletin/ros-security-page/ · Vendor Advisory
- arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-powe · Third Party Advisory
- seclists.org/fulldisclosure/2012/Apr/277 · Exploit
- www.kb.cert.org/vuls/id/889195 · Third Party Advisory
- www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-116-01A.pdf · Third Party Advisory
- www.wired.com/threatlevel/2012/04/ruggedcom-backdoor/ · Third Party Advisory
- exchange.xforce.ibmcloud.com/vulnerabilities/75244 · Third Party Advisory
- nvd.nist.gov/vuln/detail/CVE-2012-2441
- cve.org/CVERecord?id=CVE-2012-2441
More vulnerabilities in Siemens products
CVE-2025-40942CVE-2025-40941CVE-2025-40940CVE-2025-40939CVE-2025-40938CVE-2025-40937CVE-2025-40831CVE-2025-40830All 2,082
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.