Vulnerabilities · 2012 · Siemens
CVE-2012-1803
Siemens Ruggedcom Rugged Operating System vulnerability
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.
Affected products
Ruggedcom Rugged Operating System. The exact versions are in the references.
What to do now
- Check your exposureFind out whether Siemens Ruggedcom Rugged Operating System runs anywhere in your environment, including systems of suppliers.
- UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
- Set the orderSystems that can be reached from the internet come first, then the rest.
References
- www.ruggedcom.com/productbulletin/ros-security-page/ · Vendor Advisory
- arstechnica.com/business/news/2012/04/backdoor-in-mission-critical-hardware-threatens-powe · Third Party Advisory
- ics-cert.us-cert.gov/advisories/ICSA-12-146-01A · Third Party Advisory
- seclists.org/fulldisclosure/2012/Apr/277 · Exploit
- www.exploit-db.com/exploits/18779 · Exploit
- www.kb.cert.org/vuls/id/889195 · Third Party Advisory
- www.kb.cert.org/vuls/id/MAPG-8RCPEN · Third Party Advisory
- www.securityfocus.com/bid/53215 · Third Party Advisory
- nvd.nist.gov/vuln/detail/CVE-2012-1803
- cve.org/CVERecord?id=CVE-2012-1803
More vulnerabilities in Siemens products
CVE-2025-40942CVE-2025-40941CVE-2025-40940CVE-2025-40939CVE-2025-40938CVE-2025-40937CVE-2025-40831CVE-2025-40830All 2,082
Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.