CONTENTUM.COMA specialist. A plan. A result.

Vulnerabilities · 2017 · Rockwellautomation

CVE-2017-6015
Rockwellautomation Factorytalk Activation vulnerability

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

Affected products

Factorytalk Activation. The exact versions are in the references.

What to do now

  • Check your exposureFind out whether Rockwellautomation Factorytalk Activation runs anywhere in your environment, including systems of suppliers.
  • UpdateInstall the version in which the vendor fixed the vulnerability. The references lead to the advisory.
  • Set the orderSystems that can be reached from the internet come first, then the rest.

References

More vulnerabilities in Rockwellautomation products

Data: CVE list and the NVD. This product uses data from the NVD API but is not endorsed or certified by the NVD.